| Control Module Power Supply |
- 105-130 VAC @ 15A, single phase, 47-63 Hz
- 210-260 VAC @ 7.5A, single phase, 47-63 Hz (optional)
- Operating temperature: 0-50° C
The MTS-3030 Two Convertible Channels Module, MTS-3040 AC
Voltage Module and MTS-3060 AC Current Module receive power
from and are controlled by the MTS-3000 Control Module.
The system will operate down to 90 VAC with reduced voltage
and current outputs. For some configurations the 15A/7.5A
rating may be exceeded if all outputs are at full power.
Maximum voltage and current specifications are given for
nominal 120/240 VAC input at 20° C ambient temperature.
Ratings may be reduced with lower input voltage and higher
ambient temperature.
|
|
Output Frequency
|
- Power Line, frequency and phase locked
- Variable
- 8.000 - 99.999 Hz (0.001 Hz resolution, 0.01% accuracy)
- 100 - 499.99 Hz (0.01 Hz resolution, 0.02% accuracy)
- 500 - 1000 Hz (0.1 Hz resolution, 0.02% accuracy)
- Two independently variable frequencies are available
|
|
Time Measurement
|
- Measures interval from either fault initiation or an
external start trigger signal
- 0 - 99999 sec, auto-ranging scale
- 0 - 99999 cycles, auto-ranging scale
- Resolution: 0.1 ms/ 0.1 cycles
- Accuracy: +/- 0.5ms, +/- 1 digit
- Two wire pulse timing mode
|
|
Operational States
|
- Pre-fault, Fault (2 modes), Breaker Opening, Post Fault
and Breaker Closing
|
|
Phase Control
|
- Phase angle of all AC outputs adjustable from 0 to 360°
- Setting resolution: 0.1°
- Accuracy: +/- 0.5°
|
|
Harmonics
|
- Single harmonic, 2nd through 10th , maximum harmonic
frequency = 1000 Hz
- Harmonic amplitude 0 - 50% of fundamental
|
|
Static/Dynamic Testing Capabilities
|
- Phase to ground, phase to phase and three phase faults
- Two phase to ground faults
- Phase, frequency, voltage and current stepping
- Phase, frequency, voltage and current ramping with adjustable
ramp rates
- Programmable auto-reclose time delay and reclose-into-fault
events
- Programmable breaker opening and closing times
- Fault incidence angle control (point-on-wave)
|
|
Communication/Control
|
- Two RS-232 serial ports, for equipment under test and
for remote control, with programmable communication parameters
and flow control
- Parallel output port for printing test results
|
Minimum Configuration:
Control Module and 1 AC Voltage or 1 AC Current Module or 1 Two
Convertible Channels Module. Modules connect together in a stack
with the Control Module on the top, shipped in a hard shell shipping
case with a removable protective front cover.
|
Control Module:
|
- 15"W x 7.5"H x 11 5/8"D (38.1cm W x 19cm
H x 29.5cm D)
- Weight: 18 lbs. (8.2 kg)
- Built-in side carry handles
- Dimensions & weight include top and bottom covers
|
|
Options
|
Control Module Options:
MTS-3010 Programmable Digital I/O Module
with trigger channels
MTS-3020 DC Voltage Module (Maximum configuration:
1 per Control Module.)
Option 09 240 VAC operation for Control
Module
|
|
System Features
|
- Hard-shell shipping case with casters
25.75"W x 23.25"H x 17.25"D (65.5cm x 59cm
x 44cm) Weight: 35.5 lbs. (16.1 kg)
- Protective front cover (optional)
- Operation and Reference Manual
- 1 year warranty
Full 3-phase system weight:
Weight with control module, 3 voltage and 3 current channels,
top and bottom covers and the protective front cover - 69.8
lbs. (31.7kg).
3 Module Stack:
15"W x 18.75"H x 12.75"D (38.1cmW x 47.6cmH
x 32.4cmD – Including protective cover adds 1 1/8"D
(2.9cmD)
(Height of assembled stack is less then the total of 3
modules)
System Options:
Option 01 Heavy Duty Shipping Case
Option 02 Test Lead Kit
Option 03 Extra Manual
Option 04 Additional 1 Year extended
warranty
Option 05 DC Current Module (MTS-3010
required)
Option 06 Additional AC Voltage Channel
Option 07 Additional AC Current Channel
Option 09 240 VAC operation for CM (must
be used with options 29, 49 & 69)
|
|
MTS-3010 Digital I/O Module
This optional module installs in the Control Module
case and is used to provide timing functions and to supply
DC current to the device(s) under test.
|
- 2 Programmable inputs
NC or NO wet/dry contact inputs, 300VDC/AC maximum, fully
isolated
Start/Stop trigger inputs for fault initiation/termination
Audible and visual indication of state of 1st input
Programmable contact de-bounce delay, 0.1 - 999.9 msec,
0.1 msec resolution
- 1 Programmable auxiliary contact output, fully isolated
5A @ 300VAC, 1A @ 125VDC, 0.5A @ 250VDC, 0.35A @ 300VDC
resistive load
Breaker signal (52A/52B) simulation
Permissive/unblock signal simulation with programmable delay,
0 - 9999.0 msec, 0.1 msec resolution.
|
| OPTIONS: |
| |
Option 05 Current Source |
| |
- Maximum compliance voltage: 12V
- Setting resolution: 0.001 Amps
- Accuracy: greater of 1% of setting or 10mA
- Current Limit 2.5A, fully open and short circuit
proof
|
| |
Option 12 Digital I/O Test
Lead Kit |
|
|
MTS-3020 DC Voltage Module
This optional module installs in the Control Module
case and maybe used to supply auxiliary power to the device(s)
under test.
|
- DC voltage output 0-300 VDC @ 100W maximum
- Setting resolution: 0.1V
- Accuracy greater of 1% of setting or 0.75V
- Current Limit: 2A, fully short circuit proof
|
| OPTIONS: |
| |
Option 22 DC Voltage Test Lead
Kit Option 29 240 VAC operation |
|
MTS-3040 AC Voltage Module
|
- 3-phase wye voltage
- 0-150V rms phase to neutral, direct coupled
- 125VA maximum per channel (high range 75-150V), P.F.=1.0
- 100VA maximum per channel (low range 0-75V), P.F.=1.0
- Setting resolution: 0.01V
- Accuracy: greater of 0.25% of setting or 0.1V rms
- Fully open & short circuit proof and thermal overload
protected
|
| Physical Characteristics: |
- 15"W x 6.25"H x 11 5/8"D (38.1cm W x 15.9cm
H x 29.2cm D)
- Weight with 3 channels: 23.2 lbs (10.5 kg)
|
| OPTIONS: |
| |
Option 06 Additional AC Voltage
Channel
Option 42 AC
Voltage Test Lead Kit
Option 49 240 VAC operation
Maximum configuration: 3 Channels per Module, 2 Modules
per stack. |
|
MTS-3060 AC Current Module
|
- Direct coupled
- Fully open & short circuit proof and thermal overload
protected
- Setting resolution: 0.001 Amps rms
- Accuracy: greater of 0.25% of setting or 0.005A rms
|
| Single Channel |
- 0-25A rms maximum, 15V rms maximum
- 0-12A rms maximum, 30V rms maximum
- 275VA maximum
|
| 3 Channels in Parallel Mode |
- 0-75A rms maximum
- 600VA maximum @ 35A
- 300VA maximum @ 75A
|
| 3-Phase wye Current |
- 0-25A rms maximum per channel
|
| Physical Characteristics: |
- 15"W x 6.25"H x 11 5/8"D (38.1cm W x 15.9cm
H x 29.2cm D)
- Weight with 3 channels: 28.8 lbs. (13.1 kg)
|
| OPTIONS: |
| |
Option 07 Additional AC Current
Channel
Option 62 AC Current Test Lead
Kit
Option 69 240 VAC operation
Maximum configuration: 3 Channels per ACI Module, 2
Modules per stack. |
NOTE: All specifications are subject
to change
Download full MTS-3000
Series brochure size 362kB PDF format
Obtain complete MTS-3000
literature
MTS-3000 system
components and configurations
|