MTS-1010 Multifunction Powermeter

Highlights

  • Ten simultaneous measurements
  • Very responsive controls and displays
  • Lightweight, easy to use
  • High ampacity current inputs
  • True RMS, fully autoranging
  • Phasor display of AC quantities
  • Optimized for relay and meter applications
  • High intensity LED displays


Specifications


Power Supply
  • 120 VAC/60 Hz version: 100-130VAC at 50-70Hz
  • 240 VAC/50/50 Hz version: 220-260VAC at 47-70Hz
  • With option 04A: 12VDC

Measurements

Frequency measurement

  • Ranges: 8.00 - 99.99Hz (low scale), 8.0-500.0 Hz (high scale)
  • Resolution:
    • 0.001 Hz for 8.000-9.999 Hz input
    • 0.01 Hz for 10.00-99.99 Hz input
    • 0.1 Hz for 100.0-650.0Hz input
  • Accuracy: +/-0.01 Hz (low scale), +/- 0.1 Hz (high scale)
  • Measurement speed:
  • Measurement speed is dependent upon input frequency
    • for 60 Hz input: 2 readings/sec (normal mode), 7.5 readings/sec (high speed mode)
    • for 50 Hz input: 1.6 readings/sec (normal mode), 6.3 readings/sec (high speed mode)


Time (seconds) measurement

  • Range: 0.0ms - 9999 sec, autoranging at the end of each decade
  • Resolution: 0.1ms (lowest scale)
  • Accuracy: +/-0.5 ms (0-10 seconds), +/-0.01% +/-1LSD (10-9999 seconds)


Time (cycles) measurement

  • Range: 0.0 - 9999 cycles, autoranging at 999.9 cycles
  • Resolution: 0.1cycles (lowest scale)
  • Accuracy: +/-0.1cycles (lowest scale)


Phase measurement

  • Ranges: 0.0 to 360.0 degress or +/-180.0 degrees
  • Resolution: 0.01 degree for readings from -9.99deg to 10.00 degrees, 0.1 degree otherwise
  • Accuracy: +/-0.5 deg. down to 2V/200mA
  • Measurement speed:
    • Measurement speed is dependent upon input frequency, for 60 Hz input: 2 readings/sec (normal mode), 7.5 readings/sec (high speed mode) for 50 Hz input: 1.6 readings/sec (normal mode), 6.3 readings/sec (high speed mode)


AC/DC Voltage measurement

  • True RMS responding, DC coupled
  • Available on channel A and/or B
  • Accuracy: +/-0.5% of reading +/- 0.2% of scale
  • Ranges: 0-19.99/ 199.9/ 1999V, autoranging at 19.99, 199.9V
  • Maximum input: 600VAC continuous
  • Resolution: 0.01V (lowest scale)
  • Input impedance: 2 megohms
  • Measurement speed: 3 readings/sec (normal mode), 30 readings/sec (high speed mode)


AC Current measurement

  • True RMS responding, AC coupled
  • Available on channel A and/or B
  • Accuracy: +/-0.5% of reading +/- 0.2% of scale
  • Ranges: 0-1.999/ 19.99/ 199.9A, autoranging at 1.999, 19,99A
  • Maximum input: 35A continuous, 125A for 5 seconds
  • Resolution: 0.001A (lowest scale)
  • Measurement speed: 3 readings/sec (normal mode), 30 readings/sec (high speed mode)


Power measurement
Power measurements are calculated by the internal microprocessor from the current, voltage and phase angle measurements.


Kilowatts
  • Resolution: up to 0.001kWatt
  • Accuracy: 0.8% at P.F.=1
  • Range: -63.0 to +63.0 kW


Kilovars

  • Resolution: up to 0.001kVAR
  • Accuracy: 0.8% at P.F.=0
  • Range: -63.0 to +63.0 kVAR


Kilovoltamperes

  • Resolution: up to 0.001kVA
  • Accuracy: 0.8%
  • Range: -63.0 to +63.0 kVA


Power Factor

  • Resolution: up to 0.001
  • Accuracy: +/- 0.004 for sinusoidal inputs
  • Range: -1.000 to +1.000


External Trigger

  • Floating three-terminal inputs for start and stop triggers
  • Change of state detection for contact or AC/DC voltage (30-300V)
  • Contact inputs protected to 300V AC/DC
  • Input impedance: 60kohm minimum
  • Selectable audio tone for continuity indication of stop trigger
  • Start trigger starts timer, increases update frequency of voltage, current, phase and frequency readings
  • Stop trigger stops timer and freezes all measurement readings


RS-232C Interface

  • Data format: 8 bits, no parity, 1 start bit, 1 stop bit
  • Speed: Standard baud rates from 1100 to 9600 baud
  • Connector: Standard 25-pin female DB-25, DCE configuration
  • Permits control of all meter functions for fully automated or semi-automated testing
  • Permits automated output and recording of all measurements


Phsyical Characteristics

  • Aluminum case and frame
  • Moulded ABS plastic front/rear covers
  • Integrated carry handle/tilt stand
  • Large rear feet allow vertical operation
  • Dimensions: 10"W x 6"H x 10.5"D (254mm W x 152mm H x 267mm D)
  • Weight: 12 lbs/5.5kg


Options

  • Option 01: Cordura carry case
  • Option 02: Snap-on lead case
  • Option 03: Impedance measurement
  • Option 04A: 12VDC Operation
  • Option 04B: Battery pack
  • Option 05: High current measurement version
  • Option 06: IEEE-488 Interface
  • Option 08: W, VAR, VA display
  • Option 09: Ratio measurement
  • Option 10: Slip frequency measurement
  • Option 11: Analog outputs
  • Option 12: High intensity LED display
  • Option 14: Synchrocheck
  • Option 17: Signal processing
    Adds 3 additional measurement capabilities:
    • Low pass filter for channel A
    • Average responding AC measurement on channel A
    • Peak hold & peak responding measurement for channels A & B
  • Option 18: Extended low level phase measurement
  • Option 20: Hard-shell shipping case
  • Option 21: 10V Triggers
  • Option 23: 240V, 50Hz nominal AC line voltage input
  • Option 24: Extra manual
  • Option 25: 1 Year extended warranty. Additional year for a total of 2 years
  • Full-Service Agreement Preventative maintenance, calibration and service plan

Download full MTS-1010 Series brochure 165kB PDF format

NOTE: All specifications are subject to change